Kimo humidity switch series HST

SKU 2020701
The Kimo HST series humidity switches can be used as a humidistat in rooms or ducts. The status LED indicates if an alarm level is exceeded and the display shows the current relative humidity. The installation is very easy and the housing can be mounted in two parts making it ideal for installers.

Kimo humidity transmitter series HM110

SKU 2020707
The Kimo HM110 series is a transmitter with or without display. The HM110 is ideal to use as humidity measurement in air ducts and rooms for connection to a building management system. The installation is very easy and the housing can be mounted in two parts making it ideal for installers.

Kimo humidity transmitter series TH110

SKU 2020716
The Kimo TH110 series is a relative humidity transmitter with or without display. The TH110 is ideal to use as humidity and temperature measurement in rooms and air ducts for connection to a building management system. The installation is very easy and the housing can be mounted in two parts making it ideal for installers.

Dwyer room temperature and air humidity transmitter series RHP-E

SKU 2022767
The Dwyer RHP-E series is a combined room temperature and humidity sensor for wall mounting. There can be chosen from different accuracies and a housing with or without display. There are several outputs that allow the sensor to be read on any type of GBS.

Dwyer outdoor temperature and humidity transmitter series WHT

SKU 2020547
The Dwyer WHT series humidity transmitters measure temperature and relative humidity in the outside. The waterproof housing and sintered filter protect the sensor from weather effects. The WHT series is available with an analogue output for relative humidity and optionally also temperature.

Kimo humidity transmitter series TH210

SKU 2020728
The Kimo TH210 series is a relative humidity transmitter with or without display. The TH210 is ideal to use as temperature and humidity measurement in air ducts and rooms for connection to a building management system. The transmitter calculates the absolute humidity, dew point, wet and dry bulb temperature. For temperatures up to 180°C stainless steel sensors are available. There are also severa…

Dwyer duct mounting humidity transmitter series RHP-D

SKU 2023587
The Dwyer RHP-D series has a combined temperature and humidity sensor for installation in air ducts. There can be selected from different precision and a performance with or without display. There are several outputs that allow the sensor to be read on any type of BMS.

ATE-TR Ethernet monitoring unit with internal temperature and RH sensors

SKU 8011042
  • Measuring unit, Ethernet-based (PoE), Te/RH, display
  • Temperature range: -30°C to +60°C (± 0.4°C)
  • RH range: 0 to 100% RH (± 2.5% RH)
  • Probe length: 75mm
  • Protocols: HTTP(s), Web server (www), HTTP GET (JSON, XML), ModbusTCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocol: e-mail (SMTP), syslog
  • Power supply: Power over Ethernet (IEEE 802.3af) or 5–24 V…

ATE-1U Ethernet monitoring unit with universal input for temperature/RH or CO2 sensor

SKU 8011043
  • Measuring unit, Ethernet-based (PoE), 1x connection (Te/RH or CO2 sensor), display
  • Model: ATE-1U
  • 1x connection (4-pin Hirschmann): for Te/RH or CO2 sensor
  • Protocols: HTTP(s), Web server (www), HTTP GET (JSON, XML), ModbusTCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocol: e-mail (SMTP), syslog
  • Power supply: Power over Ethernet (IEEE 802.3af) or 5–24 V DC

ATE-TRP Ethernet monitoring unit with internal temperature, RH, and atmospheric pressure sensors

SKU 8011044
  • Measuring unit, Ethernet-based (PoE), Te/RH/Atm. Pressure, display
  • Temperature range: -30°C to +60°C (± 0.4°C)
  • RH range: 0 to 100% RH (± 2.5% RH)
  • Atm. Pressure range: 600 to 110 hPa (±1.3 hPa *)
  • Probe length: 75 mm
  • Protocols: HTTP(s), Web server (www), HTTP GET (JSON, XML), ModbusTCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protoc…

ATE-TE Ethernet monitoring unit with Pt1000 temperature probe (Cinch)

SKU 8011045
  • Measuring unit, Ethernet-based (PoE), 1x connection (for Pt1000 sensor), display
  • Model: ATE-TE
  • 1x connection (RCA): for Pt1000 sensor
  • Protocols: HTTP(s), Web server (www), HTTP GET (JSON, XML), ModbusTCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocol: e-mail (SMTP), syslog
  • Power supply: Power over Ethernet (IEEE 802.3af) or 5–24 V DC

ATE-1U-P Ethernet monitoring unit with universal input for temperature/RH or CO2 sensor and internal atmospheric pressure sensor

SKU 8011214
  • Measuring unit, Ethernet-based (PoE), Atm. Pressure and 1x external connection (Te/RH or CO2), display
  • Internal atmospheric pressure sensor
  • 1x connection: 4-pin Hirschmann connector for Te/RH or CO2 sensor
  • Protocols: HTTP(s), Web server (www), HTTP GET (JSON, XML), ModbusTCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocol: e-mail (SMTP), syslog

ATE-C-P Ethernet monitoring unit with integrated CO₂ and atmospheric pressure sensors

SKU 8011046
  • Measurement unit, Ethernet-based (PoE), with integrated CO₂ and atmospheric pressure sensor, display
  • CO₂ measuring range: 0 to 5000 ppm, accuracy ±(50 ppm + 3% of reading)
  • Atmospheric pressure measuring range: 600 to 1100 hPa (±1.3 hPa*)
  • Supported protocols: HTTP(S), web server (WWW), HTTP GET (JSON, XML), Modbus TCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocols…

ATE-2TE Ethernet Monitoring Unit with Dual Pt1000 Temperature Probe Inputs (Cinch Connectors)

SKU 8011047
  • Ethernet-Based Monitoring Unit (PoE) with Dual Pt1000 Temperature Probe Inputs and Display
  • Two Cinch inputs for connection of external Pt1000 temperature probes
  • Supported protocols: HTTP(S), web server (WWW), HTTP GET (JSON, XML), Modbus TCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocols: E-mail (SMTP), Syslog
  • Power supply: Power over Ethernet (IEEE 802.3af) or 5…

ATE-2U Ethernet Monitoring Unit with Two Universal Inputs for Temperature/Humidity or CO₂ Sensors

SKU 8011048
  • Ethernet-Based Monitoring Unit (PoE) with Two Universal Sensor Inputs and Display
  • Two inputs (4-pin Hirschmann connectors) for connecting external temperature/relative humidity or CO₂ sensors
  • Supported protocols: HTTP(S), web server (WWW), HTTP GET (JSON, XML), Modbus TCP, SNMPv1, SNMPv2c, SNMPv3
  • Alarm protocols: E-mail (SMTP), Syslog
  • Power supply: Power ov…

ATE-1U-2TE Ethernet Monitoring Unit with One Universal Input for Temperature/Relative Humidity or CO₂ Sensor and Two Pt1000 Temperature Probe Inputs

SKU 8011049
  • Ethernet-Based Monitoring Unit (PoE) with One Universal Sensor Input, Two Pt1000 Inputs, and Display
  • One 4-pin Hirschmann connector for connection of an external temperature/relative humidity or CO₂ sensor
  • Two Cinch inputs for connection of external Pt1000 temperature probes
  • Supported protocols: HTTP(S), web server (WWW), HTTP GET (JSON, XML), Modbus TCP, SNMPv1, S…

ATE-TRCP Ethernet Monitoring Unit with Integrated Temperature, Relative Humidity, Atmospheric Pressure, and CO₂ Sensors

SKU 8011050
  • Ethernet-Based Monitoring Unit (PoE) with Integrated Temperature, Relative Humidity, CO₂ and Atmospheric Pressure Sensors, and Display
  • Temperature measuring range: -30°C to +60°C (±0.4°C)
  • Relative humidity measuring range: 0 to 100% RH (±2.5% RH)
  • CO₂ measuring range: 0 to 5000 ppm, accuracy ±(50 ppm + 3% of reading)